.ppt   Cryo-Tracker Level Temperature and Mass Gauging Fluid Sensors.ppt (Size: 164 KB / Downloads: 183)
Commercial Applications


Cryogenic storage and transport tanks
Home oxygen vessels
Medevac helicopter and military field hospital oxygen-generating systems
Automobiles running on liquid hydrogen or liqufied natural gas
Reply
summer project pal
Active In SP
**

Posts: 308
Joined: Jan 2011
#2
11-01-2011, 11:22 PM

Cryo-Tracker Level, Temperature, and Mass Gauging Fluid Sensors

.ppt   Cryo-Tracker.ppt (Size: 164 KB / Downloads: 90)


Behavior of Sub-cooled Propellants in Room Temp.
Fig: Liquid Nitrogen unloaded from a small a Dewar Flask to a bucket in a laboratory.
Dewar Flask
Fig: A 25 l liquid nitrogen laboratory Dewar flask.
Inner wall linings are silvered to reduce heat leakage.
Flexible Sensing Probe
Probe is made of series of polyimide layers of thickness 0.0254 mm.
Rakes made of stainless steel tubing, wire, and phenolic insulators weigh (6.70 g/cm).
Internal Structure of Cryo-Tracker
Silicon diode sensors incorporated with the probe.
Conductor Traces which constitute the rake of the temp- element

Installed Cryo-Tracker Probe
Cryo-Tracker probe 60 ft. long.
2.5 cm wide.
containing 26 silicon diode sensors.
It’s weight is less than 0.59 kg.
Stratification of Sub-cooled Propellants
The heat leak causes the propellant to warm and stratify due to natural buoyancy forces.
Cryo-Tracker
Initially designed for incorporating in the propellant vessels of reusable launch vehicles.
Purpose of Cryo-Tracker
For knowing the amount of propellant loaded in.
For knowing the liquid & ullage temperature.
For knowing liquid level.
Mass Gauging Method
The entire liquid and ullage temperature profile is first obtained.
Tank pressure can then be used to calculate a liquid density profile.
Liquid density profile is integrated over the known tank volume.
Dual-Purpose Probe.
Temperature measured using silicon diode sensors.
Liquid level detection accuracy is a function of the sensor spacing.
For 12 inch sensor spacing, the overall liquid level accuracy is ± 6 inches.
Performance
Consistent thermal response can be
seen between the sensing elements in
a dual-element probe when it’s thermal-cycled in liquid nitrogen.
Hot-Fire Test (anomaly condition)
The probe is also capable of measuring transient fluid temperature changes.
Figure : Tracking the rapid change in liquid oxygen temperature when warm gases injected into the tank mixed the contents.
Advantages of Cryo-Tracker
Operating Costs
Accuracy
Reliability
Safety
Efficiency
Scalability
Flexibility
Commercial Applications
Cryogenic storage and transport tanks
Home oxygen vessels
Medevac helicopter and military field hospital oxygen-generating systems
Automobiles running on liquid hydrogen or liqufied natural gas

Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  robots in radioactive environment full report project report tiger 14 16,578 27-04-2015, 07:00 PM
Last Post: Guest
  Pistonless Pump for Rockets full report and ppt project topics 8 10,488 15-11-2014, 04:08 PM
Last Post: mkaasees
  DRAG REDUCTION IN SHIPS USING MICROBUBBLES TECHNOLOGY full report project report tiger 4 7,452 24-03-2014, 04:27 PM
Last Post: seminar project topic
  Testing Of Bearings on Sound and Vibration Quality full report seminar class 1 2,450 09-10-2013, 03:16 PM
Last Post: Guest
  machine gun full report project report tiger 3 5,630 08-10-2013, 07:04 PM
Last Post: pc-alert
  micromachining full report project report tiger 4 10,091 02-09-2013, 10:10 AM
Last Post: study tips
  SUSPENSION SYSTEM full report seminar topics 18 29,535 20-08-2013, 07:43 PM
Last Post: vishnuts
  Multi Air Engine Full Report study tips 0 499 18-06-2013, 04:00 PM
Last Post: study tips
  Full Report on Smart materials in Automobile study tips 0 673 06-06-2013, 04:52 PM
Last Post: study tips
  pulse detonation engine full report project report tiger 3 9,834 31-05-2013, 09:13 AM
Last Post: study tips