#1
14-10-2010, 10:24 AM


Prepared by:
Ron Hranac


Digitally Modulated Carrier Amplitude



•When measuring the amplitude of a digitally modulated carrier, make certain you are measuring its average power level

•Use test equipment that performs automated measurements, rather than trying to make error-prone manual measurements that require bandwidth, IF filter, log amplifier and detection corrections


for more details, please visit
downloads.net1.cc/Other%20stuff/CaTV%20docs/Downstream%20RF%20Troublshooting.pdf



Attached Files
.pdf   Cisco Downstream RF Troublshooting.pdf (Size: 438.79 KB / Downloads: 67)