ABSTRACT
In this paper controller design for voltage sag ride-through in hybrid fuel
cell/energy storage distributed power generation system has been presented. As the
amount of fuel cell power generation and other Distributed Generation (DG) with
power electronic in the grid grows, it becomes unacceptable to disconnect generat-
ing units every time a disturbance occurs, as was common practice in he past.
Keeping the VSC on line during unbalanced voltage sags becomes thus a very
critical issue. Hence, modeling, controller design, and simulation study of a hybrid
distributed generation system are investigated. The physical model of the fuel cell
stack, battery energy storage and the dynamic models of power conditioning units
are described. Based on the classification of unbalanced faults that can occur in the
grid, resulting in voltage sags at the bus where the hybrid power system is con-
nected, the maximum current that the converter valves must be bale to withstand is
calculated. Simulation results are given to show the overall system performance
including active power control and voltage sag ride-through capability of the hy-
brid distributed generation system.
Use Search at http://topicideas.net/search.php wisely To Get Information About Project Topic and Seminar ideas with report/source code along pdf and ppt presenaion
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  dynamic voltage restorer ppt jaseelati 0 267 15-01-2015, 02:48 PM
Last Post: jaseelati
  analog digital hybrid modulation ppt presentation jaseelati 0 154 15-01-2015, 02:40 PM
Last Post: jaseelati
  battery charger using scr wikipedia jaseelati 0 192 13-01-2015, 03:44 PM
Last Post: jaseelati
  DETECTION OF TRAIN COLLISION THROUGH GPS AND GSM project uploader 1 1,010 27-09-2014, 12:00 AM
Last Post: Michaelbog
  SINGLE PHASE AC VOLTAGE CONTROLLER WITH R & RL LOADS project girl 1 1,391 25-09-2014, 11:03 AM
Last Post: Michaelbog
  Grid Voltage Regulation Utilizing Storage Batteries in PV Solar seminar ideas 7 7,507 10-01-2014, 04:27 PM
Last Post: seminar project topic
  PULSE WIDTH MODULATION TECHNIQUES FOR VOLTAGE –FED INVERTERS PPT seminar projects maker 0 805 24-09-2013, 04:41 PM
Last Post: seminar projects maker
  crystalline silicon solar cell Abstract seminar projects maker 0 451 13-09-2013, 02:59 PM
Last Post: seminar projects maker
  VOLTAGE SHUNT FEEDBACK AMPLIFIER seminar projects maker 0 412 13-09-2013, 02:33 PM
Last Post: seminar projects maker
  Effect of Voltage and Load Variations on Efficiencies of a Motor-Pump System Report seminar projects maker 0 544 12-09-2013, 12:39 PM
Last Post: seminar projects maker