Intelligent Energy Saving System
Thread Rating:
  • 1 Vote(s) - 3 Average
  • 1
  • 2
  • 3
  • 4
  • 5
seminar surveyer
Active In SP
**

Posts: 3,541
Joined: Sep 2010
#1
09-10-2010, 03:51 PM



.doc   p-0329--intelligent_energy_saving.doc (Size: 563 KB / Downloads: 963)

Abstract

Intelligent Energy Saving System can be used in places like where lighting is very important. The libraries will be well illuminated with many lamps. When people are not present at a reading place the lighting can be made OFF and when they are present, the lighting made ON. All these can be done through by Dimming circuit and PIR sensor.

If a person entering to the monitored area, the PIR sensors activates and sense the person, gives to the micro controller. The Infrared energy emitted from the living body is focused by a Fresnel lens segment. Then only the PIR sensor activates. After sensing the person LDR checks the light intensity of the monitored area, whether it is bright or dark. Depending on the LDR output, the lamp may be ON / OFF by using Dimmer circuit.

By using this system we can adjust the speed of Fan according to the room temperature measured by Thermostat, which is connected to the micro controller.

To display the room temperature of PIR mode operation we are using the LCD display.


Introduction

Intelligent Energy Saving System, the aim of the project and implimentation is to save the energy. In this project and implimentation we are using various sensors, controlling and display.

However, in this project and implimentation work the basic signal processing of various parameters which are temperature, LDR, Smoke sensor. For measuring various parameters values, various sensors are used and the output of these sensors are converted to control the parameters. The control circuit is designed using micro-controller. The outputs of all the three parameters are fed to micro-controller. The output of the micro-controller is used to drive the LCD display, so that the value of each parameter can be displayed. In addition to the LCD display micro-controller outputs are also used to driver a relay independently. This relay energizes and de-energizes automatically according to the condition of the parameter.

Reply
project report helper
Active In SP
**

Posts: 2,270
Joined: Sep 2010
#2
12-10-2010, 03:23 PM


.doc   p-0329--intelligent_energy_saving.doc (Size: 563 KB / Downloads: 252)
Intelligent Energy Saving System

INTRODUCTION


Intelligent Energy Saving System, the aim of the project and implimentation is to save the energy. In this project and implimentation we are using various sensors, controlling and display.

However, in this project and implimentation work the basic signal processing of various parameters which are temperature, LDR, Smoke sensor. For measuring various parameters values, various sensors are used and the output of these sensors are converted to control the parameters. The control circuit is designed using micro-controller. The outputs of all the three parameters are fed to micro-controller. The output of the micro-controller is used to drive the LCD display, so that the value of each parameter can be displayed. In addition to the LCD display micro-controller outputs are also used to driver a relay independently. This relay energizes and de-energizes automatically according to the condition of the parameter.

1.1 OBJECTIVE OF THE PROJECT: -

The aim of the project and implimentation is to save the energy or power, used in places like libraries where lighting is very important for the people who come to read books. So, the libraries will be well illuminated with many lamps.
At the same time when people are not present at a particular reading place the lighting can be made off by using Dimmer and when people come to that area, according to the LDR lighting can be made sufficiently brighter.
Reply
project report helper
Active In SP
**

Posts: 2,270
Joined: Sep 2010
#3
01-11-2010, 05:08 PM



.doc   Energy Management - kar.doc (Size: 645.5 KB / Downloads: 343)
Intelligent Energy Saving System

ABSTRACT

This project and implimentation is proposing the household energy management and warning system for energy saving solution. The overall control scheme is mainly governed by a PIC16F877A microcontroller. There are four subsystems to be concerned (i) air-condition’s inverter control, (ii) lamp brightness control, (iii) power switching control (for general loads such as television, radio, fan, etc.), (iv) house hold electricity usage warning system. This whole system can monitor the power usage and display through a LCD monitor. Then, it can warn the users through LED bulbs when the power usage is getting close to the monthly prescribed energy usage levels. An experiment conducted by installing this system in an apartment room has shown a satisfactory result in reducing power usage level.
Reply
pbrao
Active In SP
**

Posts: 1
Joined: Dec 2010
#4
23-12-2010, 10:56 PM

i want the components list to be used for this Intelligent energy saving system..... please reply me....Smile
i need the components list of this project and implimentation..... pls send immediately
Reply
seminar surveyer
Active In SP
**

Posts: 3,541
Joined: Sep 2010
#5
24-12-2010, 09:35 AM

you can find more details from the attached files. so please download them
Reply
ANAND S.S
Active In SP
**

Posts: 1
Joined: Feb 2011
#6
11-02-2011, 08:19 PM

Please Help Me With Brief Synopsis
Reply
nagaveni ganjigunta
Active In SP
**

Posts: 1
Joined: Jul 2011
#7
13-07-2011, 08:00 PM

hi i want this project and implimentation documentation plzzzzzzzzz send my eail id.Smile
Reply
seminar addict
Super Moderator
******

Posts: 6,592
Joined: Jul 2011
#8
14-07-2011, 10:39 AM

you can refer these page details of "Intelligent Energy Saving System"link bellow


topicideashow-to-intelligent-energy-saving-system?pid=26616#pid26616

topicideashow-to-intelligent-energy-saving-system?pid=26932#pid26932

topicideashow-to-intelligent-energy-saving-system?pid=29353#pid29353
Reply
aweadeolu
Active In SP
**

Posts: 4
Joined: Jul 2011
#9
22-07-2011, 07:36 AM

Fantastic Project to help manage energy for future use. Can i have the the full circuit diagram
Reply
seminar addict
Super Moderator
******

Posts: 6,592
Joined: Jul 2011
#10
22-07-2011, 10:12 AM

To get more information about the topic " Intelligent Energy Saving System " please refer the link below

topicideashow-to-intelligent-energy-saving-system?pid=26616#pid26616

topicideashow-to-intelligent-energy-saving-system?pid=26932#pid26932

topicideashow-to-intelligent-energy-saving-system?pid=29353#pid29353
Reply
tulikab
Active In SP
**

Posts: 2
Joined: Nov 2011
#11
14-11-2011, 12:22 PM

hi
can i please get the code of this using 8051 microcontroller
thanx in advance
Reply
seminar addict
Super Moderator
******

Posts: 6,592
Joined: Jul 2011
#12
15-11-2011, 09:49 AM


to get information about the topic" Intelligent Energy Saving System" refer the link bellow

topicideashow-to-auditorium-controller-embedded-based-intelligent-auditorium-controller
Reply
ramireddykurri@gmail.com
Active In SP
**

Posts: 1
Joined: Jan 2012
#13
30-01-2012, 11:44 AM

technical seminar and presentation of intelligent energy saving system
Reply
Guest
Thinking To Register

 
#14
17-08-2012, 09:09 AM

How to interface pir sensor with microcontroller
Reply
seminar girl
Active In SP
**

Posts: 519
Joined: Aug 2012
#15
17-08-2012, 09:46 AM



to get information about the topic "Intelligent Energy Saving System" related topic refer the link bellow

topicideashow-to-intelligent-energy-saving-system?pid=26616#pid26616
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Wireless intelligent billing trolley for shopping malls using Zigbee and RFID seminar ideas 1 2,834 03-09-2014, 02:51 PM
Last Post: kale sandip suryabhan
  COIN PREPAID ENERGY METER madan.aakanksha 1 508 25-04-2014, 09:57 AM
Last Post: seminar project topic
  Life Saving Embedded smart paper boy 3 2,022 03-10-2013, 08:40 PM
Last Post: Guest
  DESIGN AND SIMULATION OF AN INTELLIGENT TRAFFIC CONTROL SYSTEM pdf seminar projects maker 0 702 26-09-2013, 04:48 PM
Last Post: seminar projects maker
  HUMAN TRACKING SYSTEM FOR SMART FAN AND LIGHTING SYSTEM ppt seminar projects maker 0 500 23-09-2013, 04:36 PM
Last Post: seminar projects maker
  Developing an Intelligent e-Restaurant with a Menu Recommender for Customer-Centric seminar projects maker 0 314 14-09-2013, 03:55 PM
Last Post: seminar projects maker
  AUTOMATIC ENERGY SAVING SYSTEM WITH HUMAN HEAT DETECTION PPT seminar projects maker 0 616 14-09-2013, 12:08 PM
Last Post: seminar projects maker
  Grid Interfacing Inverter of Renewable Energy Sources to Improve the Power pdf study tips 0 386 29-08-2013, 04:55 PM
Last Post: study tips
  Doubly-Fed Induction Generator for Variable Speed Wind Energy Conversion Systems pdf study tips 0 360 29-08-2013, 04:30 PM
Last Post: study tips
  ENERGY SAVING USING MICRO CONTROLLER PPT study tips 0 497 28-08-2013, 04:57 PM
Last Post: study tips