Low-Cost ZIGBEE and GSM SMS-Based Conductor Temperature and Sag Monitoring system
Thread Rating:
  • 0 Vote(s) - 0 Average
  • 1
  • 2
  • 3
  • 4
  • 5
computer science topics
Active In SP
**

Posts: 610
Joined: Jun 2010
#1
29-06-2010, 02:19 PM


Abstract
This paper deals with the design, construction, instrumentation and testing of a GSM and ZIGBEE based monitoring system for the measurement of Overhead High Voltage (HV) Conductor Temperature and Sag. The main advantage of this concept is the real time direct measurement of the parameters (i.e., conductor sag and temperature) needed for the operation of the transmission system without intermediate measurement of conductor tension and ambient weather conditions, by which the temperature controlling of transmission lines conductors is realized the stoppage caused by raised temperature can be avoided and some accidents caused by the increased temperature can be avoided. The principle and the feature of GSM SMS and ZIGBEE communication are analyzed. The construction of this system is outlined, and the force modal of calculating the variety of the sag due to the increased temperature of conductors is built. Finally, the software and hardware design of the online temperature monitoring unit of conductors and fittings are outlined. In this paper, a self-designed industrial GSM module is selected to finish the transmission and the decoding of the monitoring data through AT command and coding of short message PDU

read full report
ijest.info/docs/IJEST10-02-04-06.pdf
Use Search at http://topicideas.net/search.php wisely To Get Information About Project Topic and Seminar ideas with report/source code along pdf and ppt presenaion
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  PHS BASED ONLINE VEHICLE TRACKING SYSTEM full report project topics 6 8,559 07-01-2016, 11:33 AM
Last Post: Guest
  Embedded based customized wireless message circular system for college, industries seminar class 1 2,771 08-12-2015, 09:18 PM
Last Post: upendra malisetti
  voltage sag analysis ppt jaseelati 0 172 05-01-2015, 04:38 PM
Last Post: jaseelati
  Anti Theft System for Electronic Equipments using Inertial MEMS Sensor and ZigBee seminar ideas 2 1,931 11-10-2014, 06:29 PM
Last Post: Guest
  WEATHER MONITORING AND INSTRUMENT CONTROL SYSTEM USING MICROCONTROLLER project report tiger 6 7,097 04-10-2014, 08:55 PM
Last Post: OsKFAHX
  Mitter – Bitter Monitoring System Using Android Smartphone’s PPT study tips 4 2,193 26-09-2014, 06:18 PM
Last Post: Guest
  Wireless intelligent billing trolley for shopping malls using Zigbee and RFID seminar ideas 1 2,834 03-09-2014, 02:51 PM
Last Post: kale sandip suryabhan
  MICROCONTROLLER BASED DAM GATE CONTROL SYSTEM full report seminar class 13 10,321 13-07-2014, 11:33 PM
Last Post: Guest
  DOOR LOCKING SECURITY SYSTEM UING GSM FULL REPORT seminar class 11 10,837 14-06-2014, 08:07 PM
Last Post: lagua2012
  REMOTE NOTICE BOARD IMPLEMENTATION USING GSM COMMUNICATION project uploader 2 1,272 09-05-2014, 10:00 AM
Last Post: seminar project topic