MAGNETICALLY CONTROLLED REACTORS TO ENHANCE TRANSMISSION CAPABILITY & SAVE ENERGY


Magnetically Controlled Reactor

A Magnetically controlled Reactor is device in Which DC Pulsing Through a Part of The Power Winding Changes The Duration to Period Ratio of The Magnetic Core Saturation There By Changing The Inductance And Inductive Susceptance
MCRs Are Powerful Low “inertia Inductors In Which Reactive power Can Be Regulated From .01 To 1.0 Time Rated Power
MCRs Significantly Reduced Idle Mode Power Losses They Also Increase Reliability Of Electrical Grids & Power Line Operating Conditions



MCRs Based On Two Principles

The Generation And Control Of The Direct Components Of The Magnetic Flux In The MCRs Two Cores In The Reactive Winding By The Use Of Semiconductor Switches
MCR Is Performed Magnetic Saturation Of The Two Cores Under Rated Conditions, When The Saturation Magnetization Generated By The Direct Components Of The Grid Frequency Period
Basic Electrical Circuits Of Controllable Circuits
3 To 35 kv For Shunt Reactor Power Supply Facility


Shunt Reactor For 110 To 500kv Grid

Single Line Connection Of Three Phase 180MVA, 500KV Shunt MCR



Voltage Stabilization At a 110 kv Substation is Performed Automatic
Smooth Change Of The Consumed Power Of Reactor In According With Mismatch Signal Generated By Control System
The Consumed Current Of Reactor Is Changed a Result Of Direct Current Produced By a Thirstier converter Magnetizing Its Magnetic System
When The Voltage Increases To 2.5% Above The Given Pre- set Value, consumed Power is Changed Range 0.25% To 25 MVA With Equivalent Time Constant



Compensation Of Excess Charge Power Of Transmission Lines Is Carried Automatically
Smooth Regulation Of Single Phase MCRs Phase Currents And phase Voltage Over Time:
List Of Available Reactors:
Single Phase MCR As Automatic Ground Fault Neutralized:
Neutralizes Automation Ground Fault Capacitive In Electrical Net works With Isolated Neutral
Prevents Transmission Of Single Phase Ground Fault To Multi Phase Short Circuits



Principles Of Operation:


Automatic Adjustment & Control System when Ever Ground Fault occur It Will Sends Control Signal To The MCR Converter
When Ground Fault Occur, The Reactor Reduces The Resulting Current At The Damage Point To A Negligible Value This process Is Fully Automatic
Under Normal Condition The Single Phase MCR is Not Saturated, Eliminating Resonance Over Voltage In The Neutral Line
Thos Is Al So Used In Three Phase Electric Grid And Consumers In This Case Filter Is Connected To The Reactor To The Three Phase Network



Winding Connections:

Phase Of Net Work Winding Of MCR 25/110 Reactor Are Y-Connected & Grounded.
MCRs 25/110 Control Winding Of Phase Are Delta-Connected.
MCR 25/110 Control Systems Are Connected To Control Inputs Of Transformer With Built In Thyristor Converter To Current Transformer At MCR Phases & Substation Voltage Transformer At 11kv Bus.



Operating Conditions:

These MCRs Are Designed For Out Door Operation
The Associated Transformer With Built In Thirstier Converter Is Al So Designed For Outdoor Operation. It Is Placed In An Oil Impression Tank For Natural Cooling
We Can Control, Adjustment & Monitoring System For Indoor Installation On a Substation Switchboard Panel
Use Search at http://topicideas.net/search.php wisely To Get Information About Project Topic and Seminar ideas with report/source code along pdf and ppt presenaion
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  AUTOMATIC FAULT DETECTION AND ISOLATION IN TRANSMISSION LINES project uploader 2 1,255 13-07-2016, 03:54 PM
Last Post: jaseela123
  Renewable energy ppt seminar tips 1 603 11-04-2016, 09:26 AM
Last Post: mkaasees
  Contactless Energy Transfer System computer science crazy 54 30,995 12-02-2015, 10:22 PM
Last Post: Guest
  gearless transmission project jaseelati 0 276 30-01-2015, 02:16 PM
Last Post: jaseelati
  adaptive piezoelectric energy harvesting circuit ppt jaseelati 0 318 09-01-2015, 03:45 PM
Last Post: jaseelati
  HEAD MOTION CONTROLLED POWER WHEELCHAIR seminar class 8 7,469 21-10-2013, 10:30 PM
Last Post: Guest
  Op Amp Regulator with Series-Pass Transistor seminar projects maker 0 511 26-09-2013, 03:29 PM
Last Post: seminar projects maker
  Tidal energy which is clean, green sustainable PPT seminar projects maker 0 577 26-09-2013, 02:53 PM
Last Post: seminar projects maker
  HVDC TRANSMISSION seminar tips 2 3,336 23-09-2013, 10:07 AM
Last Post: seminar projects maker
  REPORT ON FLEXIBLE AC TRANSMISSION SYSTEMS seminar projects maker 0 572 21-09-2013, 03:55 PM
Last Post: seminar projects maker