Introduction

Fuzzy control is a practical alternative for a variety of challenging control applications since it provides a convenient method for constructing non-linear controllers via the use of heuristic information. Since heuristic information may come from an operator who has acted as "a human in the loop" controller for a process. In the fuzzy control design methodology, a set of rules on how to control the process is written down and then it is incorporated into a fuzzy controller that emulates the decision making process of the human.

In other cases, the heuristic information may come from a control engineer who has performed extensive mathematical modelling, analysis and development of control algorithms for a particular process. The rest of the process is the same as the earlier case. The ultimate objective of using fuzzy control is to provide a user-friendly formalism for representing and implementing the ideas we have about how to achieve high performance control. Apart from being a heavily used technology these days, fuzzy logic control is simple, effective and efficient. In this paper, the structure, working and design of a fuzzy controller is discussed in detail through an in-depth analysis of the development and functioning of a fuzzy logic pH controller.

PH Control

To illustrate the application of fuzzy logic, the remaining section of the paper is directed towards the design and working of a pH control system using fuzzy logic.

PH is an important variable in the field of production especially in chemical plants, sugar industries, etc. PH of a solution is defined as the negative of the logarithm of the hydrogen ion concentration, to the base 10. I.e., PH= -log 10 [H+]
Let us consider the stages of operation of a sugar industry, where PH control is required. The main area of concern is the clarification of raw juice of sugarcane. The raw juice will be having a PH of 5.1 to 5.5. The clarified juice should ideally be neutral. I.e., the set point should be a PH of 7. The process involves addition of lime and SO2 gas for clarifying the raw juice. The addition of these two are called liming and sulphitation respectively. Since the process involves continuous addition of lime and SO2 ; lime has a property of increasing the PH of the clarified juice. This is the principle used for PH control in sugar industries. The PH of the raw juice is measured and this value is compared to the set point and this is further used for changing the diameter of the lime flow pipe as per the requirement.

The whole process can be summarised as follows. The PH sensor measures the PH. This reading is amplified and recorded. The output of the amplifier is also fed to the PH indicator and interface. The output of this block is fed to the fuzzy controller. The output of fuzzy controller is given to the stepper motor drive. This inturn adjusts the diameter of lime flow pipe as per the requirement. Thus, the input to the fuzzy controller is the PH reading of the raw juice.

The output of the fuzzy controller is the diameter of the lime flow pipe valve or a quantity that controls the diameter of the lime flow pipe valve like a DC current, voltage, etc. The output obtained from the fuzzy controller is used to drive a stepper motor which inturn controls the diameter of the value opening of the lime flow pipe. This output tends to maintain the pH value of sugar juice to a target value. A detailed description of the design and functioning of the fuzzy controller is given in the following section
Use Search at http://topicideas.net/search.php wisely To Get Information About Project Topic and Seminar ideas with report/source code along pdf and ppt presenaion
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  electronic diesel control edc pdf jaseelati 0 319 17-02-2015, 03:09 PM
Last Post: jaseelati
  fuzzy vault matlab code jaseelati 0 379 23-12-2014, 04:32 PM
Last Post: jaseelati
  vhdl code for elevator control system jaseelati 0 251 23-12-2014, 03:27 PM
Last Post: jaseelati
  Ultrasonic Sensor Based DC Motor Control Using LabVIEW seminar class 5 5,250 05-05-2014, 10:08 AM
Last Post: seminar project topic
  TOPOLOGY CONTROL IN MOBILE AD HOC NETWORKS WITH COOPERATIVE COMMUNICATIONS seminar flower 4 2,323 24-03-2014, 04:35 PM
Last Post: seminar project topic
  ADVANCED VEHICLE SECURITY SYSTEM WITH THEFT CONTROL AND ACCIDENT NOTIFICATION seminar ideas 2 2,468 10-01-2014, 02:07 PM
Last Post: seminar project topic
  GESTURE CONTROL AND THE NEW AND INTELLIGENT MAN-MACHINE INTERFACE seminar ideas 8 5,495 15-09-2013, 01:39 PM
Last Post: Guest
  Project Monitoring and Control ppt seminar projects maker 0 421 12-09-2013, 02:37 PM
Last Post: seminar projects maker
  Report on Open & Closed Loop Control System study tips 0 477 29-08-2013, 04:55 PM
Last Post: study tips
  Automation using PLCs SCADA and Telemetry Process Control and Data Acquisition pdf study tips 0 491 13-08-2013, 04:56 PM
Last Post: study tips