seminar projects crazy
Active In SP
**

Posts: 604
Joined: Dec 2008
#1
31-01-2009, 12:40 AM


PPTC circuit-protection devices are used to protect against harmful over current surges and over-temperature faults. Like traditional fuses, these limit the flow of dangerously high current during fault conditions. The PPTC device, however, automatically resets after the fault is cleared and power to the circuit is removed. Understanding the precise nature of these devices can help designers develop more reliable equipment and reduce warranty, service and repair costs. Improvements in size, cost and performance have resulted in wide spread acceptance of polymeric positive temperature coefficient (PPTC) devices, but several product names and commonly used terms like ?resettable fuse? have resulted in some confusion regarding the precise nature of these devices.Protecting an electronic circuit front damage due to excessive current or heat is the primary function of many circuit protection technologies. In the past, this protection took the form of a fuse or fusible link, but in many of today?s applications resettable devices such as PPTC devices, ceramic PTC devices, bimetal breakers and thermostats are the preferred solution.These devices do not require replacement after a fault event, and allow the circuit to return to the normal operating condition after the power has been removed and/or the over-current condition is eliminated. This resettable functionality can help manufacturers reduce warrants, service and repair costs, however, proper application requires an understanding of how the device resets and the circuit conditions that must be met before reset will occur.Although resettable fuse? is a common ten used in describing PPTC devices, they are in fact, non-linear thermistors and not fused A PTC device is a non-linear thermistor that limits current. Because under a fault condition all PTC devices go into a high resistance state, normal operation can still result in hazardous voltage being present in parts of the circuit. It is important that the circuit designers recognize critical differences between the two devices.Fused are current-interruption devices, and once a fuse ?blows? the electrical circuit is broken, and there is no longer current flowing through the fuse. This electrical interruption (or open circuit) is a permanent condition.However, once a PPTC device trips, there is a small amount of current flowing through the device PPTC devices require a low-joule heating leakage current or external heat source in order to maintain their tripped condition. Once the fault condition is removed, this heat source is eliminated. The device can then return to a low-resistance status and the circuit is restored.
Use Search at http://topicideas.net/search.php wisely To Get Information About Project Topic and Seminar ideas with report/source code along pdf and ppt presenaion
Reply
destiny88
Active In SP
**

Posts: 4
Joined: Jul 2009
#2
28-07-2009, 08:30 PM

need more about this topic
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  high speed electronics devices ppt jaseelati 0 292 23-01-2015, 02:18 PM
Last Post: jaseelati
  high speed electronics devices ppt jaseelati 0 274 07-01-2015, 02:31 PM
Last Post: jaseelati
  BASIC INSTRUMENTATION MEASURING DEVICES AND BASIC PID CONTROL study tips 0 392 20-07-2013, 12:58 PM
Last Post: study tips
  APPLICATION OF MEMS/NEMS DEVICES ppt study tips 0 497 01-07-2013, 02:40 PM
Last Post: study tips
  Nanoelectronics and Devices ppt study tips 0 384 17-06-2013, 04:14 PM
Last Post: study tips
  APPLICATIONS OF MEMS DEVICES IN NANOSATELLITE PPT study tips 0 388 30-05-2013, 02:46 PM
Last Post: study tips
  Haptic Devices pdf study tips 0 349 14-05-2013, 01:23 PM
Last Post: study tips
  Microwave Devices PPT study tips 0 474 08-05-2013, 04:09 PM
Last Post: study tips
  Transferred Electron Devices PPT study tips 0 615 06-03-2013, 10:11 AM
Last Post: study tips
  Report on Nano Generator to Power Nano Devices study tips 0 656 02-03-2013, 04:17 PM
Last Post: study tips