Many structures have their fundamental frequencies of vibration within the range
of frequencies where the energy of most of the earthquake ground motions is a maximum. In such cases a structure will amplify the ground vibrations and produce accelerations, which increases from the base of the structure to its top. Besides producing undesirable levels of acceleration in the structure, these amplified structural motions can cause large stresses in structural elements and large relative displacements between different parts of the structure. This can result in permanent damage to parts of the structure or even to catastrophic collapse. The amplified accelerations throughout the structure act on the occupants and contents of the structure and can cause harm and damage to occupants and contents even when no structural damage occurs.
The use of seismic isolations bearings permits the structure to be less strong than
would be required if the structure were to have it base fixed to the ground. This results in a lower cost and lower weight of structure. It is an exceptionally effective method for the practical and economical retrofitting of structures that to do not meet current seismic
standards, or for which a higher degree of safety is desired. Especially, for retrofit of those structure that cannot afford to stop functioning, this method found to be very useful. This would be especially important for such structures as hospitals, emergency centers, communication centers, disaster response center, power stations etc. Proper isolation of structures such as nuclear power plants, oil refineries, chemical plants and processing plants can also prevent potentially catastrophic secondary harm from occurring due to damage of such systems as a consequence of an earthquake. For many industries and businesses, the most significant benefit deriving from seismic isolation can be the prevention of loss of operation during and after a major earthquake. However, for effective functioning of seismic isolation, it is necessary to have isolation devices that can fulfill the essential requirements as well as be durable, less expensive and require minimum maintenance during the lifetime of structure... .
Use Search at http://topicideas.net/search.php wisely To Get Information About Project Topic and Seminar ideas with report/source code along pdf and ppt presenaion
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  Use of FRP Composite Materials in Seismic Retrofitting of Structures pdf seminar projects maker 0 742 21-09-2013, 01:01 PM
Last Post: seminar projects maker
  Seismic strengthening Of Reinforced buildings PPT study tips 0 681 01-05-2013, 03:05 PM
Last Post: study tips
  RETROFITTING BY SEISMIC ISOLATION OF CIVIL BUILDINGS IN ARMENIA INCLUDING SCHOOL study tips 0 598 13-02-2013, 10:36 AM
Last Post: study tips
  SEISMIC RETROFITTING OF EARTHQUAKE-DAMAGED CONCRETE COLUMNS BY LATERAL PRE-TENSIONING seminar flower 0 625 22-10-2012, 01:54 PM
Last Post: seminar flower
  Seismic behavior of isolated bridges full report seminar tips 0 543 20-10-2012, 02:18 PM
Last Post: seminar tips
  A Comparative Study on Seismic Provisions Made in Indian and International Building seminar flower 0 696 28-09-2012, 10:36 AM
Last Post: seminar flower
  Seismic Behavior Of Isolated Bridges computer science crazy 4 4,716 11-08-2012, 11:30 AM
Last Post: manojdeosarkar
  SEISMIC RETROFIT OF HISTO RIC BUILDING STRUCTURES project uploader 0 443 26-07-2012, 11:40 AM
Last Post: project uploader
  RESEARCH AND DEVELOPMENT ON SEISMIC DESIGN METHOD seminar ideas 0 587 09-07-2012, 12:48 PM
Last Post: seminar ideas
  SEISMIC RETROFITTING OF CONCRETE BUILDINGS full report project report tiger 18 14,179 16-06-2012, 11:09 AM
Last Post: seminar ideas