Stereoscopic Passive Millimeter-Wave Imaging and Ranging
Thread Rating:
  • 0 Vote(s) - 0 Average
  • 1
  • 2
  • 3
  • 4
  • 5
project report helper
Active In SP
**

Posts: 2,270
Joined: Sep 2010
#1
19-10-2010, 05:07 PM





Stereoscopic Passive Millimeter-Wave Imaging and Ranging

Thomas Lüthi and Christian Mätzler, Senior Member, IEEE



Abstract—

This paper presents the first stereoscopic range measurements
at a wavelength of 3.3 mmand discusses the accuracy of
this new method. The synthesis of passive millimeter-wave imaging
and stereoscopy combines the advantages of both principles, naturally
looking high-contrast images and superior poor-weather performance
(compared to visible and infrared wavelengths), as well
as the passive ranging capability. Our setup using two antennas
with a half-power beamwidth (HPBW) of 0.9 and a stereoscopic
baseline of 1.15mallows ranging with an accuracy of 10% up to a
distance of 300 m. The range resolution improves with increasing
stereoscopic baseline, lower radiometer noise, narrower antenna
beams, and higher scene contrast. For scenes with sufficient contrast,
the directional resolution is considerably better than the antenna
HPBW. Thus, massive oversampling of the scene in the plane
of the stereoscopic baseline is required. For our setup, an oversampling
factor of 36 is optimal. Since additional ranging errors result
from nonstationary scenes, fast scanning imagers should be
applied

for more :->
117.55.241.6/library/ieee/2005/microwave%20theory%20and%20techniques/Vol.53.Issue.8/Stereoscopic%20Passive%20Millimeter-Wave%20Imaging%20and%20Ranging.pdf
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  artificial vision systems for the blind using ultrasonic wave jaseelati 0 270 07-01-2015, 02:49 PM
Last Post: jaseelati
  Magnetic Resonance Imaging (MRI) ppt study tips 0 581 20-08-2013, 03:59 PM
Last Post: study tips
  Video/Imaging Fixed-Point Digital Signal Processor pdf study tips 0 450 20-06-2013, 04:36 PM
Last Post: study tips
  ANTENNAS AND WAVE PROPAGATION pdf project girl 1 820 20-04-2013, 04:46 PM
Last Post: study tips
  Radio Detection and Ranging Report study tips 1 487 07-03-2013, 11:29 AM
Last Post: study tips
  Plane Wave Propagation and Reflection in 3-D project girl 0 277 04-02-2013, 10:41 AM
Last Post: project girl
  Passive integrator and differentiator circuits seminar tips 0 505 15-01-2013, 04:22 PM
Last Post: seminar tips
  TERAHERTZ IMAGING TECHNIQUE report project girl 0 371 21-12-2012, 03:22 PM
Last Post: project girl
  Magnetic Resonance Imaging computer science crazy 4 1,745 20-11-2012, 04:40 PM
Last Post: project girl
  Breaking the Wave seminar tips 0 291 08-11-2012, 06:13 PM
Last Post: seminar tips