ABSTRACT

This paper focuses on a shunt active filter based on the detection of harmonic voltages at the point of installation. The objective of the active filter is to attenuate harmonic propagation resulting from series/parallel resonance between capacitors for power factor correction and line inductors in a power distribution line. The active filter acts as a low resistor to the external circuit for harmonic frequencies, and it is installed on the end bus of the power distribution line, just like a 50 O terminator installed on the end terminal of a signal transmission line. Therefore, the function of the active filter is referred to as harmonic termination in this paper. Experimental results obtained from a laboratory system rated at 200 V and 20 kW verify that the active filter for the purpose of harmonic termination has the capability of harmonic damping throughout the power distribution line

INTRODUCTION
NONLINEAR loads such as high-power diode/thyristor rectifiers, cycloconverters, and arc furnaces draw nonsinusoidal currents from utility grids. A single low-power diode rectifier used as a utility interface in an electric appliance produces a negligible amount of harmonic current. However, multiple low-power diode rectifiers can inject a large amount of current harmonics into power distribution systems. These harmonic-producing loads contribute to the degradation of power quality in transmission/distribution systems.

for full report
please read ieeexplore.ieeeiel5/28/16612/00767015.pdf?arnumber=767015
Use Search at http://topicideas.net/search.php wisely To Get Information About Project Topic and Seminar ideas with report/source code along pdf and ppt presenaion
Reply

Important Note..!

If you are not satisfied with above reply ,..Please

ASK HERE

So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page

Quick Reply
Message
Type your reply to this message here.


Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  AUTOMATIC FAULT DETECTION AND ISOLATION IN TRANSMISSION LINES project uploader 2 1,255 13-07-2016, 03:54 PM
Last Post: jaseela123
  detection and localization of multiple spoofing attackers in wireless networks ppt jaseelati 0 267 17-01-2015, 02:52 PM
Last Post: jaseelati
  missile detection and auto destroy system jaseelati 0 329 15-01-2015, 04:30 PM
Last Post: jaseelati
  dynamic voltage restorer ppt jaseelati 0 267 15-01-2015, 02:48 PM
Last Post: jaseelati
  DETECTION OF TRAIN COLLISION THROUGH GPS AND GSM project uploader 1 1,012 27-09-2014, 12:00 AM
Last Post: Michaelbog
  SINGLE PHASE AC VOLTAGE CONTROLLER WITH R & RL LOADS project girl 1 1,391 25-09-2014, 11:03 AM
Last Post: Michaelbog
  Compensation of harmonic currents utilizing AHC computer science crazy 6 5,265 08-03-2014, 02:50 PM
Last Post: seminar project topic
  Grid Voltage Regulation Utilizing Storage Batteries in PV Solar seminar ideas 7 7,508 10-01-2014, 04:27 PM
Last Post: seminar project topic
  Occupant Detection and Temperature Control seminar tips 1 758 18-12-2013, 01:44 AM
Last Post: mwesoze3rd
  To verify the characteristics of Low pass and High pass filter seminar projects maker 0 381 26-09-2013, 03:20 PM
Last Post: seminar projects maker